Heat Pumps

AUX 24K SEER25 LC Single-Zone Mini Split Indoor Unit — AMAR24HP230V1CH

AUX 24K SEER25 LC Single-Zone Mini Split Indoor Unit — AMAR24HP230V1CH

AUX 24K SEER25 LC Single-Zone Mini Split Indoor Unit — AMAR24HP230V1CH is a outdoor unit. Key verified specifications include 22,500 BTU, 230V, R32, SEER2 25, HSPF2 10.5. The AUX AMAR24HP230V1CH is the indoor high wall unit for the AUX SEER25 LC C-Series single-zone mini split system. It is paired with the AMAR24HP230V1CO outdoor unit and is designed for high-efficiency residential or light commercial cooling and heating applications. This system provides 22,500 BTU/h rated cooling capacity and 24,000 BTU/h rated heating capacity at 47°F. AUX’s official SEER25 LC page lists this model as a 24K single-zone C-Series system and highlights features such as voice control, AUX app control, 4D airflow, low ambient cooling, easy installation, I-Feel, automatic self-cleaning, LED display, and child lock. INDOOR UNIT FEATURES • High wall indoor unit design • SEER25 LC C-Series single-zone system • 24K capacity class • Wall-mounted installation • Voice control • AUX app / Wi-Fi control • 4D airflow • Low ambient cooling • I-Feel temperature sensing • Automatic self-cleaning • LED display • Child lock • Easy installation design

<table style="border-collapsecollapse; width: 100%;"><tbody><tr><th style="border: none; padding: 8px; text-align: left;">Item</th><th style="border: none; padding: 8px; text-align: left;">Parameter</th></tr><tr><td style="border: none; padding: 8px; text-align: left;"><strong>General</strong></td><td style="border: none; padding: 8px; text-align: left;"><strong>Value</strong></td></tr><tr><td style="border: none; padding: 8px; text-align: left;">SKU</td><td style="border: none; padding: 8px; text-align: left;">AMAR24HP230V1CH</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Model</td><td style="border: none; padding: 8px; text-align: left;">AMAR24HP230V1CH</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Brand</td><td style="border: none; padding: 8px; text-align: left;">Aux</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Category</td><td style="border: none; padding: 8px; text-align: left;">Heat Pumps</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Product Type</td><td style="border: none; padding: 8px; text-align: left;">Outdoor unit</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Unit Type</td><td style="border: none; padding: 8px; text-align: left;">Indoor Unit</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Product Line</td><td style="border: none; padding: 8px; text-align: left;">AUX SEER25 LC</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Series</td><td style="border: none; padding: 8px; text-align: left;">C-Series</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Matched Outdoor Unit</td><td style="border: none; padding: 8px; text-align: left;">AMAR24HP230V1CO</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Operating Mode</td><td style="border: none; padding: 8px; text-align: left;">Cooling &amp; Heating</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">AHRI Certified Reference Number</td><td style="border: none; padding: 8px; text-align: left;">214290024</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Air Flow Rate</td><td style="border: none; padding: 8px; text-align: left;">940 / 833 / 742 / 636 CFM</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Indoor Drain Size</td><td style="border: none; padding: 8px; text-align: left;">5/8&quot;</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Recommended Breaker Size</td><td style="border: none; padding: 8px; text-align: left;">25 A</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Installation Type</td><td style="border: none; padding: 8px; text-align: left;">High Wall / Wall-Mounted</td></tr><tr><td style="border: none; padding: 8px; text-align: left;"><strong>Performance</strong></td><td style="border: none; padding: 8px; text-align: left;"><strong>Value</strong></td></tr><tr><td style="border: none; padding: 8px; text-align: left;">System Type</td><td style="border: none; padding: 8px; text-align: left;">Single-Zone</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">System Model</td><td style="border: none; padding: 8px; text-align: left;">AMAR24HP230V1C</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Capacity Class</td><td style="border: none; padding: 8px; text-align: left;">24K</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Cooling Capacity</td><td style="border: none; padding: 8px; text-align: left;">22,500 BTU/h</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Cooling Capacity Range</td><td style="border: none; padding: 8px; text-align: left;">4,300–28,500 BTU/h</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Cooling Power Input Rated</td><td style="border: none; padding: 8px; text-align: left;">1610 W</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Cooling Operating Range</td><td style="border: none; padding: 8px; text-align: left;">5°F to 125°F</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Heating Capacity at 47°F</td><td style="border: none; padding: 8px; text-align: left;">24,000 BTU/h</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Heating Capacity Range</td><td style="border: none; padding: 8px; text-align: left;">5,300–31,000 BTU/h</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Heating Power Input at 47°F</td><td style="border: none; padding: 8px; text-align: left;">1750 W</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Heating Capacity at 17°F</td><td style="border: none; padding: 8px; text-align: left;">22,400 BTU/h</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Heating Capacity at 5°F</td><td style="border: none; padding: 8px; text-align: left;">21,500 BTU/h</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Heating Capacity at -5°F</td><td style="border: none; padding: 8px; text-align: left;">14,300 BTU/h</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Heating Operating Range</td><td style="border: none; padding: 8px; text-align: left;">-13°F to 75°F</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Sound Pressure Level — Cooling</td><td style="border: none; padding: 8px; text-align: left;">51 / 48 / 44 / 39 / 34 dB(A)</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Sound Pressure Level — Heating</td><td style="border: none; padding: 8px; text-align: left;">50 / 48 / 43 / 39 dB(A)</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Capacity</td><td style="border: none; padding: 8px; text-align: left;">22,500 BTU</td></tr><tr><td style="border: none; padding: 8px; text-align: left;"><strong>Energy Efficiency</strong></td><td style="border: none; padding: 8px; text-align: left;"><strong>Value</strong></td></tr><tr><td style="border: none; padding: 8px; text-align: left;">SEER2</td><td style="border: none; padding: 8px; text-align: left;">25</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">HSPF2</td><td style="border: none; padding: 8px; text-align: left;">10.5</td></tr><tr><td style="border: none; padding: 8px; text-align: left;"><strong>Electrical Data</strong></td><td style="border: none; padding: 8px; text-align: left;"><strong>Value</strong></td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Power Supply</td><td style="border: none; padding: 8px; text-align: left;">208–230V / 1 Phase / 60Hz</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">MCA</td><td style="border: none; padding: 8px; text-align: left;">15 A</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">MOCP</td><td style="border: none; padding: 8px; text-align: left;">25 A</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Voltage</td><td style="border: none; padding: 8px; text-align: left;">230V</td></tr><tr><td style="border: none; padding: 8px; text-align: left;"><strong>Dimensions / Weight</strong></td><td style="border: none; padding: 8px; text-align: left;"><strong>Value</strong></td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Package Dimensions</td><td style="border: none; padding: 8px; text-align: left;">52-3/4&quot; x 17-33/64&quot; x 13-31/32&quot;</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Net Dimensions</td><td style="border: none; padding: 8px; text-align: left;">48-21/32&quot; x 14-1/16&quot; x 10-1/8&quot;</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Net Weight</td><td style="border: none; padding: 8px; text-align: left;">16 kg</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Max. Height Difference</td><td style="border: none; padding: 8px; text-align: left;">65 ft</td></tr><tr><td style="border: none; padding: 8px; text-align: left;"><strong>Refrigerant / Piping</strong></td><td style="border: none; padding: 8px; text-align: left;"><strong>Value</strong></td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Gas Pipe Size</td><td style="border: none; padding: 8px; text-align: left;">5/8&quot;</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Liquid Pipe Size</td><td style="border: none; padding: 8px; text-align: left;">1/4&quot;</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Min. Pipe Length</td><td style="border: none; padding: 8px; text-align: left;">9 ft</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Max. Pipe Length</td><td style="border: none; padding: 8px; text-align: left;">100 ft</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Refrigerant Type</td><td style="border: none; padding: 8px; text-align: left;">R32</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Refrigerant</td><td style="border: none; padding: 8px; text-align: left;">R32</td></tr></tbody></table>
Request A Quote
← Back to AUX