Heat Pumps

GREE FLR30HP230V1R32AH All Match Floor Ceiling R32 30,000 BTU Floor/Ceiling Indoor Unit

GREE FLR30HP230V1R32AH All Match Floor Ceiling R32 30,000 BTU Floor/Ceiling Indoor Unit

<p>The <strong>GREE FLR30HP230V1R32AH</strong> is a versatile floor/ceiling indoor unit designed to deliver strong air distribution with flexible installation options. Its slim horizontal cabinet can be mounted near the floor or suspended from the ceiling, allowing it to adapt to spaces where traditional wall-mounted units may not be ideal. GREE positions the All Match Floor Ceiling R32 series for open spaces and rooms with unique layouts, with R32 refrigerant, multi-directional airflow, swing louver control, refrigerant sensor, and remote or wired controller options. </p><p>When matched with the <strong>LIV30HP230V1R32AO</strong> outdoor unit, the system delivers <strong>30,000 BTU/H rated cooling capacity at 95°F</strong> and <strong>30,000 BTU/H rated heating capacity at 47°F</strong>. The system is rated at <strong>21.0 SEER2</strong>, <strong>11.45 EER2</strong>, and <strong>8.0 HSPF2</strong>, with cooling operation from <strong>-4°F to 122°F</strong> and heating operation from <strong>-13°F to 75°F</strong>.</p><p><br></p><p><strong>30,000 BTU floor/ceiling indoor unit</strong></p><p>Part of the <strong>GREE All Match Floor Ceiling R32</strong> series</p><p>Matching outdoor unit: <strong>LIV30HP230V1R32AO</strong></p><p><strong>R32 refrigerant with refrigerant sensor</strong></p><p>Floor-standing or ceiling-mounted installation</p><p>Multi-directional air flow</p><p>Quiet operation and multi-speed fan</p><p>Wireless remote with LCD display included</p><p><strong>XE72-44/E wired controller included</strong></p><p>Indoor centrifugal fan</p><p><strong>4-speed indoor fan</strong></p><p>Blue fin anti-corrosion coating</p><p>Low ambient cooling and heating</p><p>Self-diagnosis and power failure memory recovery</p>

Details<table><tbody><tr><td data-row="1">SpecificationDetails</td></tr><tr><td data-row="2">Brand</td><td data-row="2">GREE</td></tr><tr><td data-row="3">Series</td><td data-row="3">All Match Floor Ceiling R32</td></tr><tr><td data-row="4">Model</td><td data-row="4">FLR30HP230V1R32AH</td></tr><tr><td data-row="5">Product Type</td><td data-row="5">Floor/Ceiling Indoor Unit</td></tr><tr><td data-row="6">System Type</td><td data-row="6">Mini-Split Heat Pump Indoor Unit</td></tr><tr><td data-row="7">Nominal Capacity</td><td data-row="7">30,000 BTU/H</td></tr><tr><td data-row="8">Matching Outdoor Unit</td><td data-row="8">LIV30HP230V1R32AO</td></tr><tr><td data-row="9">Refrigerant</td><td data-row="9">R32</td></tr><tr><td data-row="10">Rated Cooling Capacity @95°F</td><td data-row="10">30,000 BTU/H</td></tr><tr><td data-row="11">Cooling Capacity Range</td><td data-row="11">2,390–37,500 BTU/H</td></tr><tr><td data-row="12">Rated Heating Capacity @47°F</td><td data-row="12">30,000 BTU/H</td></tr><tr><td data-row="13">Heating Capacity Range</td><td data-row="13">5,800–33,400 BTU/H</td></tr><tr><td data-row="14">Heating Capacity @17°F</td><td data-row="14">24,000 BTU/H</td></tr><tr><td data-row="15">Heating Capacity @5°F</td><td data-row="15">19,400 BTU/H</td></tr><tr><td data-row="16">SEER2</td><td data-row="16">21.0</td></tr><tr><td data-row="17">EER2</td><td data-row="17">11.45</td></tr><tr><td data-row="18">HSPF2</td><td data-row="18">8.0</td></tr><tr><td data-row="19">COP @5°F</td><td data-row="19">1.80</td></tr><tr><td data-row="20">Airflow</td><td data-row="20">706–1,000 CFM</td></tr><tr><td data-row="21">Indoor Sound Pressure Level</td><td data-row="21">43–53 dB(A)</td></tr><tr><td data-row="22">Dehumidification</td><td data-row="22">7.40 pt/hr</td></tr><tr><td data-row="23">Indoor Unit Dimensions</td><td data-row="23">47-1/4 in. L x 9-1/4 in. D x 26-3/16 in. H</td></tr><tr><td data-row="24">Indoor Package Dimensions</td><td data-row="24">53-11/16 in. L x 11-13/16 in. W x 30-5/16 in. H</td></tr><tr><td data-row="25">Indoor Net Weight</td><td data-row="25">70.6 lb</td></tr><tr><td data-row="26">Indoor Gross Weight</td><td data-row="26">83.8 lb</td></tr><tr><td data-row="27">Outdoor Unit</td><td data-row="27">LIV30HP230V1R32AO</td></tr><tr><td data-row="28">Outdoor Sound Pressure Level</td><td data-row="28">62 dB(A)</td></tr><tr><td data-row="29">Outdoor Dimensions</td><td data-row="29">39-3/8 in. L x 15-13/16 in. D x 29-3/8 in. H</td></tr><tr><td data-row="30">Outdoor Net Weight</td><td data-row="30">116.8 lb</td></tr><tr><td data-row="31">Outdoor Gross Weight</td><td data-row="31">127.9 lb</td></tr><tr><td data-row="32">Refrigerant Charge</td><td data-row="32">56.4 oz R32</td></tr><tr><td data-row="33">Additional Refrigerant Charge</td><td data-row="33">0.4 oz/ft</td></tr><tr><td data-row="34">Piping Connection</td><td data-row="34">1/4 in. liquid x 5/8 in. gas</td></tr><tr><td data-row="35">Pre-Charge Length</td><td data-row="35">25 ft</td></tr><tr><td data-row="36">Pipe Length Range</td><td data-row="36">10–131 ft</td></tr><tr><td data-row="37">Max Pipe Elevation</td><td data-row="37">82 ft</td></tr><tr><td data-row="38">Power Supply</td><td data-row="38">208–230V / 1 Phase / 60Hz, powered by outdoor unit</td></tr><tr><td data-row="39">Voltage Range</td><td data-row="39">187–253V</td></tr><tr><td data-row="40">Rated Current, Cooling</td><td data-row="40">18 A</td></tr><tr><td data-row="41">Rated Current, Heating</td><td data-row="41">19.7 A</td></tr><tr><td data-row="42">MOCP</td><td data-row="42">30 A</td></tr><tr><td data-row="43">MCA</td><td data-row="43">27 A</td></tr><tr><td data-row="44">Interconnecting Wire Size</td><td data-row="44">14 AWG / 4</td></tr><tr><td data-row="45">Cooling Operating Range</td><td data-row="45">-4°F to 122°F</td></tr><tr><td data-row="46">Heating Operating Range</td><td data-row="46">-13°F to 75°F</td></tr></tbody></table><p><br></p>
Request A Quote
← Back to Gree