GREE, FLEXX Eco 16, 16 SEER, High ESP, Top & Horizontal Flow, Air Handler Unit, 60KBTU, 208/1/60, IDU, GUD60AH2/D-D(U)


SUBMITTAL DATA FLEXX 16 SERIES: GUD60AH2/D-D(U) Experience exceptional comfort and convenience with our Inverter U-Match Series Air Conditioners. Combining central air conditioner comfort with the easy installation of mini split units, these air conditioners feature a corrosion-resistant pre-painted steel casing and a low-noise compressor with advanced protections. Enjoy efficient cooling with the hydrophilic aluminum fin and inner groove copper pipe condenser coil. Energy Efficiency FLEXX 16 SERIES 60K inverter u-match series - offer high operating efficiency and cost efficiency Achieved UL certificate - meet different requirements from customers Home Comfort Connect supply-air outlets to duct - make the temperature and humidity even in room Units with filters - easily accessible from the rear of the unit Convenient Operation Flexible Installation - Air-supply or air-return type, condensation water exit direction etc can be selected flexibly Easy Maintenance - evaporator coils are constructed of quality inner groove copper tube and hydrophilic aluminum fin Reliable Function Timer and time display - customizable timer settings for convenient operation Temperature - °F/°C switch, temperature display, E-heater, temperature compensation Others - Memory, 4-way valve energizing Warranty Coverage Airtek/GREE proudly backs all their models with a robust manufacturer's warranty. This comprehensive warranty spans an impressive 10+2 years, safeguarding your investment. Rest assured, any warranty claims you may have will be efficiently handled by Airtek/GREE's, guaranteeing top-tier customer support and satisfaction. The 10+2 year warranty encompasses the compressor, while other parts enjoy coverage for 5 years. With this warranty, you can trust in the long-term protection of your purchase, ensuring you receive the utmost quality.
| <table style="width | 100%; border-collapse: collapse;"> <tbody> <tr> <th style="padding: 8px; text-align: left; border: none; font-weight: bold;">Capacity</th> <th style="padding: 8px; text-align: left; border: none; font-weight: bold;"></th> </tr> <tr> <td style="padding: 8px; text-align: left; border: none;">Cooling</td> <td style="padding: 8px; text-align: left; border: none;">54000 Btu/h</td> </tr> <tr> <td style="padding: 8px; text-align: left; border: none;">Heating</td> <td style="padding: 8px; text-align: left; border: none;">54000 Btu/h</td> </tr> <tr> <th style="padding: 8px; text-align: left; border: none; font-weight: bold;">Power Input</th> <th style="padding: 8px; text-align: left; border: none; font-weight: bold;"></th> </tr> <tr> <td style="padding: 8px; text-align: left; border: none;">Cooling</td> <td style="padding: 8px; text-align: left; border: none;">5.36 kW</td> </tr> <tr> <td style="padding: 8px; text-align: left; border: none;">Heating</td> <td style="padding: 8px; text-align: left; border: none;">5.15 kW</td> </tr> <tr> <th style="padding: 8px; text-align: left; border: none; font-weight: bold;">SEER 2/ HSPF2</th> <th style="padding: 8px; text-align: left; border: none; font-weight: bold;"></th> </tr> <tr> <td style="padding: 8px; text-align: left; border: none;">SEER</td> <td style="padding: 8px; text-align: left; border: none;">15.20</td> </tr> <tr> <td style="padding: 8px; text-align: left; border: none;">HSPF2</td> <td style="padding: 8px; text-align: left; border: none;">7.80</td> </tr> <tr> <th style="font-weight: bold; padding: 8px; text-align: left; border: none;">Indoor Unit</th> <td style="padding: 8px; text-align: left; border: none;">GUD60AH2/D-D(U)</td> </tr> <tr> <th style="font-weight: bold; padding: 8px; text-align: left; border: none;">Power Supply</th> <td style="padding: 8px; text-align: left; border: none;">208/230V-1Ph-60Hz</td> </tr> <tr> <th style="font-weight: bold; padding: 8px; text-align: left; border: none;">Fan</th> <td style="padding: 8px; text-align: left; border: none;"></td> </tr> <tr> <th style="font-weight: bold; padding: 8px; text-align: left; border: none;">Drive</th> <td style="padding: 8px; text-align: left; border: none;">Direct</td> </tr> <tr> <th style="font-weight: bold; padding: 8px; text-align: left; border: none;">Motor Output</th> <td style="padding: 8px; text-align: left; border: none;">0.75x1 kW</td> </tr> <tr> <th style="font-weight: bold; padding: 8px; text-align: left; border: none;">Air Flow</th> <td style="padding: 8px; text-align: left; border: none;">2550/(1500) m(CFM)</td> </tr> <tr> <th style="font-weight: bold; padding: 8px; text-align: left; border: none;">Rated Ext. Static Pressure</th> <td style="padding: 8px; text-align: left; border: none;">125/(0.50) Pa (InWg)</td> </tr> <tr> <th style="font-weight: bold; padding: 8px; text-align: left; border: none;">Ext. Static Pressure Range</th> <td style="padding: 8px; text-align: left; border: none;">0-250 (0-1.0) Pa (InWg)</td> </tr> <tr> <th style="font-weight: bold; padding: 8px; text-align: left; border: none;">Sound Pressure Level (H/ML)</th> <td style="padding: 8px; text-align: left; border: none;">54 dB(A)</td> </tr> <tr> <th style="font-weight: bold; padding: 8px; text-align: left; border: none;">Air Filter</th> <td style="padding: 8px; text-align: left; border: none;">Metal</td> </tr> <tr> <th style="font-weight: bold; padding: 8px; text-align: left; border: none;">Drain Piping</th> <td style="padding: 8px; text-align: left; border: none;">25.4â Ä¢1.2 mm/(1â Ä¢0.05) inch</td> </tr> <tr> <th style="font-weight: bold; padding: 8px; text-align: left; border: none;">Outline Dimensions (WxDxH)</th> <td style="padding: 8px; text-align: left; border: none;">630â Ä¢540â Ä¢1320 mm/(24-13/16â Ä¢21-1/4x51.968) inch</td> </tr> <tr> <th style="font-weight: bold; padding: 8px; text-align: left; border: none;">Net Weight</th> <td style="padding: 8px; text-align: left; border: none;">86.0 kg/(189.6) lb</td> </tr> </tbody> </table> |