PULAR R32 SERIES OUTDOOR UNIT: GWH18AUDXF-D6DNA1A/O


PULAR R32 SERIES OUTDOOR UNIT: GWH18AUDXF-D6DNA1A/O 18,000 BTU Outdoor Unit | 208-230V | 1Ph | 60Hz | R32 Built for durability and dependable performance, the PULAR R32 outdoor unit is designed to operate efficiently in a wide range of temperatures, delivering consistent heating and cooling power to keep your space comfortable all year round. Engineered with eco-friendly R32 refrigerant, it offers higher efficiency and a lower environmental impact. Its robust construction ensures reliable operation in both residential and light-commercial applications. Energy Efficiency The Pular outdoor unit incorporates GREE’s advanced inverter technology to optimize compressor performance, reducing energy consumption while maintaining consistent output: High SEER2 (26.0) and EER2 (15) ratings for maximum efficiency. Eco-friendly R32 refrigerant with lower Global Warming Potential (GWP). Optimized power usage for both cooling and heating cycles. Wide operating temperature range: cooling from -29°C to 50°C (-20°F to 122°F) and heating from -30°C to 30°C (-22°F to 86°F). Reliable Function Built to withstand harsh environments, the outdoor unit offers stable operation and enhanced protection features: Copper tube / aluminum fin coil with Blue Fin coating for corrosion resistance (500 hrs salt spray tested). Automatic fault detection and system protection. Quiet operation at just 62 dB(A) to minimize outdoor noise disturbance. Stable performance under low voltage conditions. Compact, space-saving design suitable for tight installations. Convenience & Installation The Pular outdoor unit is designed for easy installation and maintenance: Pre-charged for 24.6 ft (7.5 m) of piping length. Additional refrigerant charge capability for extended pipe runs. Max piping length: 65 ft (19.81 m) and height difference of 40 ft (12.2 m). 1/4" liquid and 3/8" gas pipe connections for compatibility. Warranty Coverage GREE backs the PULAR R32 outdoor unit with a robust 10+2 year manufacturer’s warranty. This warranty covers the compressor for the full duration and other parts for 5 years, ensuring long-term peace of mind and reliable service.
| <table style="border-collapse | collapse; width: 100%; text-align: center;"> <tr style="background-color:#f2f2f2; font-weight:bold;"> <td colspan="2">Product #</td> <td>GWH18AUDXF-D6DNA1A/I<br>GWH18AUDXF-D6DNA1A/O</td> </tr> <tr><td colspan="3" style="background:#f2f2f2; font-weight:bold;">Technical Performance</td></tr> <tr><td>Voltage</td><td>Volts</td><td>208/230</td></tr> <tr><td>Cooling capacity (Nominal)</td><td>W (BTU/hr)</td><td>5275 (18000)</td></tr> <tr><td>Cooling capacity (Min ~ Max)</td><td>W (BTU/hr)</td><td>1500 ~ 6500 (5118 ~ 22178)</td></tr> <tr><td>Heating capacity (Nominal)</td><td>W (BTU/hr)</td><td>5275 (18000)</td></tr> <tr><td>Heating capacity (Min ~ Max)</td><td>W (BTU/hr)</td><td>1300 ~ 5660 (4436 ~ 19310)</td></tr> <tr><td>Used cooling power input</td><td>W</td><td>1315</td></tr> <tr><td>Used heating power input</td><td>W</td><td>1349</td></tr> <tr><td>Used rated input</td><td>W</td><td>2350</td></tr> <tr><td>Rated current</td><td>A</td><td>11.5</td></tr> <tr><td>MCA</td><td>A</td><td>16</td></tr> <tr><td>MOCP</td><td>A</td><td>20</td></tr> <tr><td>SEER2</td><td>-</td><td>24.5</td></tr> <tr><td>HSPF2</td><td>-</td><td>9.0</td></tr> <tr><td>EER2</td><td>BTU/hr·W</td><td>13.65</td></tr> <tr><td>EER</td><td>W/W</td><td>4.01</td></tr> <tr><td>COP</td><td>W/W</td><td>3.91</td></tr> <tr><td>AHRI number</td><td>-</td><td>216052270</td></tr> <tr><td>ENERGY STAR</td><td>-</td><td>✔</td></tr> <tr><td colspan="3" style="background: #f2f2f2; font-weight:bold;">Indoor Unit</td></tr> <tr><td>Dehumidification</td><td>pt/hr (L/hr)</td><td>3.80 (1.8)</td></tr> <tr><td>Air flow volume</td><td>cfm</td><td>589 / 500 / 441 / 412 / 383 / 353 / 324</td></tr> <tr><td>Sound level (H/M/L)</td><td>dB (A)</td><td>43 / 39 / 33</td></tr> <tr><td>Fan motor power output</td><td>W</td><td>50</td></tr> <tr><td>Fan motor RLA</td><td>A</td><td>0.60</td></tr> <tr><td>Deflector stepper motor power output</td><td>W</td><td>1.5</td></tr> <tr><td>Net weight</td><td>lb (kg)</td><td>29.8 (13.5)</td></tr> <tr><td colspan="3" style="background: #f2f2f2; font-weight:bold;">Outdoor Unit</td></tr> <tr><td>Air flow volume</td><td>m³/hr</td><td>3600</td></tr> <tr><td>Sound level</td><td>dB (A)</td><td>69</td></tr> <tr><td>Compressor power input</td><td>W</td><td>1196</td></tr> <tr><td>Compressor LRA</td><td>A</td><td>22</td></tr> <tr><td>Compressor RLA</td><td>A</td><td>10.35</td></tr> <tr><td>Fan motor power output</td><td>W</td><td>60</td></tr> <tr><td>Fan motor RLA</td><td>A</td><td>1.35</td></tr> <tr><td>Refrigerant volume (R32)</td><td>oz (g)</td><td>40.6 (1150)</td></tr> <tr><td>Net weight</td><td>lb (kg)</td><td>94.8 (43)</td></tr> <tr><td>Operating ambient temp (Cooling)</td><td>°C (°F)</td><td>-29 ~ 50 (-20 ~ 122)</td></tr> <tr><td>Operating ambient temp (Heating)</td><td>°C (°F)</td><td>-30 ~ 30 (-22 ~ 86)</td></tr> <tr><td colspan="3" style="background:#f2f2f2; font-weight:bold;">Connection Piping / Refrigerant</td></tr> <tr><td>Pre-charge length</td><td>ft (m)</td><td>24.6 (7.5)</td></tr> <tr><td>Additional refrigerant charge</td><td>oz/ft (g/m)</td><td>0.2 (16)</td></tr> <tr><td>Liquid pipe outer diameter</td><td>in.</td><td>1/4</td></tr> <tr><td>Gas pipe outer diameter</td><td>in.</td><td>1/2</td></tr> <tr><td>Maximum height difference</td><td>ft (m)</td><td>82 (25)</td></tr> <tr><td>Maximum total length</td><td>ft (m)</td><td>131.2 (40)</td></tr> </table> |