Gree

PULAR R32 SERIES: GWH24AUDXH-D6DNA1A/I Wall Mounted Ductless Indoor Unit

PULAR R32 SERIES: GWH24AUDXH-D6DNA1A/I Wall Mounted Ductless Indoor Unit

PULAR R32 SERIES: GWH24AUDXH-D6DNA1A/I 24,000 BTU Wall Mounted Ductless Indoor Unit | 208-230V | 1Ph | 60Hz | R32 Designed for year‑round comfort, the Pular R32 Series pairs a slim, modern look with advanced inverter technology and eco‑conscious R32 refrigerant. It delivers quiet, precise heating and cooling for bedrooms, small living rooms, home offices, and light‑commercial spaces. Energy Efficiency Enjoy stable comfort with reduced energy use, powered by GREE’s G10 inverter platform: Variable‑speed DC compressor quickly reaches set temperature and modulates to maintain it efficiently. Eco‑friendly R32 refrigerant for strong thermodynamic performance and lower GWP. Electronic Expansion Valve (EEV) for precise refrigerant control across operating conditions. Optimized heat‑exchange surface and airflow path for improved seasonal performance. Meets current North American efficiency and environmental standards. Home Comfort Engineered for quiet, targeted comfort all day and night: Multi‑speed fan with Auto, Turbo, and Quiet modes to tune airflow and sound. Up/down & left/right swing louver control for precise air delivery where you need it. Auto‑Clean function and washable filters to help maintain coil hygiene and indoor air quality. X‑FAN self‑dry to reduce moisture on the coil after cooling and help prevent mold/mildew. Dehumidify (Dry) mode to lower indoor humidity during shoulder seasons. Anti‑cold‑air warm‑up and intelligent preheating for more comfortable winter starts. Hidden LED temperature display with °C/°F toggle, memory, and power‑failure recovery. Convenient Operation Control made simple—at home or away: Remote controller included with Sleep modes, Timer, child lock, and Auto Restart. I FEEL temperature‑sensing on the remote for localized comfort at your position. Wi‑Fi‑ready (optional module) for control via the GREE+ app on iOS/Android. Filter‑clean reminder helps keep performance and air quality on track. Reliable Function Built to last with protections for real‑world conditions: Copper tube / aluminum fin coils with Blue Fin anti‑corrosion coating (500‑hour salt spray tested). Low‑voltage startup and automatic voltage adaptation for stable operation. Intelligent defrost logic for consistent winter heating performance. Self‑diagnosis with error code display; protective shutdown on abnormal conditions. Compact, quiet design suitable for residential and light‑commercial applications. Compliant with UL 60335‑2‑40 / CSA installation safety standards. Warranty Coverage GREE proudly backs all their models with a robust manufacturer's warranty. This comprehensive warranty spans an impressive 10+2 years, safeguarding your investment. Rest assured, any warranty claims you may have will be efficiently handled by GREE's, guaranteeing top-tier customer support and satisfaction. The 10+2 year warranty encompasses the compressor, while other parts enjoy coverage for 5 years. With this warranty, you can trust in the long-term protection of your purchase, ensuring you receive the upmost quality.

<table style="border-collapsecollapse; width: 100%;"> <tbody> <tr style="background-color:#f2f2f2; font-weight:bold;"> <td colspan="2">Product #</td> <td>GWH24AUDXH-D6DNA1A/I<br>GWH24AUDXH-D6DNA1A/O</td> </tr> <tr><td colspan="3" style="background:#f2f2f2; font-weight:bold;">Technical Performance</td></tr> <tr><td>Voltage</td><td>Volts</td><td>208/230</td></tr> <tr><td>Cooling capacity (Nominal)</td><td>W (BTU/hr)</td><td>6450 (22000)</td></tr> <tr><td>Cooling capacity (Min ~ Max)</td><td>W (BTU/hr)</td><td>1170 ~ 8000 (3990 ~ 27300)</td></tr> <tr><td>Heating capacity (Nominal)</td><td>W (BTU/hr)</td><td>6740 (23000)</td></tr> <tr><td>Heating capacity (Min ~ Max)</td><td>W (BTU/hr)</td><td>850 ~ 7030 (2900 ~ 24000)</td></tr> <tr><td>Used cooling power input</td><td>W</td><td>1833</td></tr> <tr><td>Used heating power input</td><td>W</td><td>2040</td></tr> <tr><td>Used rated input</td><td>W</td><td>3800</td></tr> <tr><td>Rated current</td><td>A</td><td>17</td></tr> <tr><td>MCA</td><td>A</td><td>22</td></tr> <tr><td>MOCP</td><td>A</td><td>30</td></tr> <tr><td>SEER2</td><td>-</td><td>23.5</td></tr> <tr><td>HSPF2</td><td>-</td><td>9.0</td></tr> <tr><td>EER2</td><td>BTU/hr·W</td><td>12</td></tr> <tr><td>EER</td><td>W/W</td><td>3.52</td></tr> <tr><td>COP</td><td>W/W</td><td>3.30</td></tr> <tr><td>AHRI number</td><td>-</td><td>216623541</td></tr> <tr><td>ENERGY STAR</td><td>-</td><td>✔</td></tr> <tr><td colspan="3" style="background:#f2f2f2; font-weight:bold;">Indoor Unit</td></tr> <tr><td>Dehumidification</td><td>pt/hr (L/hr)</td><td>5.07 (2.4)</td></tr> <tr><td>Air flow volume</td><td>cfm</td><td>559 / 441 / 394 / 353 / 312 / 253 / 235</td></tr> <tr><td>Sound level (H/M/L)</td><td>dB (A)</td><td>43 / 39 / 33</td></tr> <tr><td>Fan motor power output</td><td>W</td><td>50</td></tr> <tr><td>Fan motor RLA</td><td>A</td><td>0.70</td></tr> <tr><td>Deflector stepper motor power output</td><td>W</td><td>1.5</td></tr> <tr><td>Net weight</td><td>lb (kg)</td><td>29.8 (13.5)</td></tr> <tr><td colspan="3" style="background:#f2f2f2; font-weight:bold;">Outdoor Unit</td></tr> <tr><td>Air flow volume</td><td>m³/hr</td><td>3200</td></tr> <tr><td>Sound level</td><td>dB (A)</td><td>68</td></tr> <tr><td>Compressor power input</td><td>W</td><td>1330</td></tr> <tr><td>Compressor LRA</td><td>A</td><td>35</td></tr> <tr><td>Compressor RLA</td><td>A</td><td>15.3</td></tr> <tr><td>Fan motor power output</td><td>W</td><td>60</td></tr> <tr><td>Fan motor RLA</td><td>A</td><td>0.9</td></tr> <tr><td>Refrigerant volume (R32)</td><td>oz (g)</td><td>42.3 (1200)</td></tr> <tr><td>Net weight</td><td>lb (kg)</td><td>92.6 (42)</td></tr> <tr><td colspan="3" style="background:#f2f2f2; font-weight:bold;">Connection Piping / Refrigerant</td></tr> <tr><td>Pre-charge length</td><td>ft (m)</td><td>24.6 (7.5)</td></tr> <tr><td>Additional refrigerant charge</td><td>oz/ft (g/m)</td><td>0.4 (40)</td></tr> <tr><td>Liquid pipe outer diameter</td><td>in.</td><td>1/4</td></tr> <tr><td>Gas pipe outer diameter</td><td>in.</td><td>5/8</td></tr> <tr><td>Maximum height difference</td><td>ft (m)</td><td>82 (25)</td></tr> <tr><td>Maximum total length</td><td>ft (m)</td><td>131.2 (40)</td></tr> </table>
Request A Quote
← Back to Gree