GREE LIV18HP230V1R32AO Livo R32 18,000 BTU Outdoor Mini-Split Heat Pump Unit

<p>The <strong>GREE LIV18HP230V1R32AO</strong> is a single-zone outdoor condenser designed for ductless heating and cooling applications. When matched with the <strong>LIV18HP230V1R32AH</strong> indoor wall-mounted unit, the system provides <strong>18,000 BTU/H rated cooling capacity at 95°F</strong> and <strong>19,100 BTU/H rated heating capacity at 47°F</strong>. The matched system is rated at <strong>20.0 SEER2</strong>, <strong>12.35 EER2</strong>, and <strong>8.5 HSPF2</strong>. </p><p>Built for year-round performance, this Livo R32 outdoor unit supports cooling operation from <strong>0°F to 118°F</strong> and heating operation from <strong>-13°F to 75°F</strong>. It features <strong>R32 refrigerant</strong>, a <strong>GREE G20 single-cylinder 1-stage inverter compressor</strong>, blue fin coil coating, low-voltage startup, self-diagnosis, intelligent defrosting, and memory/power failure recovery.</p><p><br></p><p><strong>18,000 BTU outdoor heat pump unit</strong></p><p>Matching indoor unit: <strong>LIV18HP230V1R32AH</strong></p><p><strong>R32 refrigerant</strong></p><p>Single-zone mini-split heat pump system</p><p>Rated system efficiency: <strong>20.0 SEER2 / 12.35 EER2 / 8.5 HSPF2</strong></p><p>Cooling operating range: <strong>0°F to 118°F</strong></p><p>Heating operating range: <strong>-13°F to 75°F</strong></p><p>Outdoor sound pressure level: <strong>57 dB(A)</strong></p><p>Line set size: <strong>1/4 in. liquid x 1/2 in. gas</strong></p><p>Maximum pipe length: <strong>82 ft</strong></p><p>Maximum pipe elevation: <strong>33 ft</strong></p><p>Blue fin coating, intelligent defrosting, self-diagnosis, and memory/power failure recovery</p>
| Details | <table><tbody><tr><td data-row="1">SpecificationDetails</td></tr><tr><td data-row="2">Brand</td><td data-row="2">GREE</td></tr><tr><td data-row="3">Series</td><td data-row="3">Livo R32</td></tr><tr><td data-row="4">Model</td><td data-row="4">LIV18HP230V1R32AO</td></tr><tr><td data-row="5">Product Type</td><td data-row="5">Outdoor Heat Pump Unit / Outdoor Condenser</td></tr><tr><td data-row="6">System Type</td><td data-row="6">Single-Zone Mini-Split Heat Pump</td></tr><tr><td data-row="7">Nominal Capacity</td><td data-row="7">18,000 BTU/H</td></tr><tr><td data-row="8">Matching Indoor Unit</td><td data-row="8">LIV18HP230V1R32AH</td></tr><tr><td data-row="9">Refrigerant</td><td data-row="9">R32</td></tr><tr><td data-row="10">Rated Cooling Capacity @95°F</td><td data-row="10">18,000 BTU/H</td></tr><tr><td data-row="11">Cooling Capacity Range</td><td data-row="11">3,753–20,300 BTU/H</td></tr><tr><td data-row="12">Rated Heating Capacity @47°F</td><td data-row="12">19,100 BTU/H</td></tr><tr><td data-row="13">Heating Capacity Range</td><td data-row="13">2,730–22,500 BTU/H</td></tr><tr><td data-row="14">Heating Capacity @17°F</td><td data-row="14">15,300 BTU/H</td></tr><tr><td data-row="15">Heating Capacity @5°F</td><td data-row="15">12,100 BTU/H</td></tr><tr><td data-row="16">SEER2</td><td data-row="16">20.0</td></tr><tr><td data-row="17">EER2</td><td data-row="17">12.35</td></tr><tr><td data-row="18">HSPF2</td><td data-row="18">8.5</td></tr><tr><td data-row="19">COP @5°F</td><td data-row="19">1.75</td></tr><tr><td data-row="20">Compressor Type</td><td data-row="20">GREE G20 / Single Cylinder / 1-Stage Inverter</td></tr><tr><td data-row="21">Outdoor Sound Pressure Level</td><td data-row="21">57 dB(A)</td></tr><tr><td data-row="22">Outdoor Dimensions</td><td data-row="22">31-37/64 in. W x 21-27/32 in. H x 13-25/32 in. D</td></tr><tr><td data-row="23">Outdoor Package Dimensions</td><td data-row="23">34-21/64 in. W x 24-13/32 in. H x 15-43/64 in. D</td></tr><tr><td data-row="24">Outdoor Net Weight</td><td data-row="24">70.6 lb</td></tr><tr><td data-row="25">Outdoor Gross Weight</td><td data-row="25">76.1 lb</td></tr><tr><td data-row="26">Refrigerant Charge</td><td data-row="26">32.5 oz R32</td></tr><tr><td data-row="27">Additional Refrigerant Charge</td><td data-row="27">0.2 oz/ft</td></tr><tr><td data-row="28">Line Set Size</td><td data-row="28">1/4 in. liquid x 1/2 in. gas</td></tr><tr><td data-row="29">Pre-Charge Length</td><td data-row="29">25 ft</td></tr><tr><td data-row="30">Pipe Length Range</td><td data-row="30">10–82 ft</td></tr><tr><td data-row="31">Max Pipe Elevation</td><td data-row="31">33 ft</td></tr><tr><td data-row="32">Power Supply</td><td data-row="32">208–230V / 1 Phase / 60Hz</td></tr><tr><td data-row="33">Voltage Range</td><td data-row="33">187–253 VAC</td></tr><tr><td data-row="34">Rated Current, Cooling</td><td data-row="34">9.5 A</td></tr><tr><td data-row="35">Rated Current, Heating</td><td data-row="35">9.5 A</td></tr><tr><td data-row="36">MOCP</td><td data-row="36">15 A</td></tr><tr><td data-row="37">MCA</td><td data-row="37">13 A</td></tr><tr><td data-row="38">Interconnecting Wire Size</td><td data-row="38">14 AWG / 4</td></tr><tr><td data-row="39">Cooling Operating Range</td><td data-row="39">0°F to 118°F</td></tr><tr><td data-row="40">Heating Operating Range</td><td data-row="40">-13°F to 75°F</td></tr></tbody></table><p><br></p> |