Mitsubishi MXZ-5D36NL 36,000 BTU 5-Zone Heat Pump Unit- R454B


Mitsubishi MXZ-5D36NL 36,000 BTU 5-Zone Heat Pump Unit- R454B is a outdoor unit. Key verified specifications include 36,000 BTU, R454B, SEER2 19.20, HSPF2 9.30, EER2 12 //. Mitsubishi 36,000 BTU multi-zone outdoor heat pump (MXZ-5D36NL). This is an extremely efficient unit that can connect to a variety of indoor unit types and can handle four zones (indoor units). This system uses the new R454B refrigerant, and is the direct replacement for MXZ-4C36NA*. Compact, small chassis • Compressor overcurrent detection • Fan motor overheating/voltage protection • Freeze-prevention base pan heater equipped as standard • High-pressure protection • Quiet outdoor unit operation as low as 52 dB(A) • Variable speed INVERTER-driven compressor • Blue Fin anti-corrosion treatment
| <table style="border-collapse | collapse; width: 100%;"><tbody><tr><th style="border: none; padding: 8px; text-align: left;">Item</th><th style="border: none; padding: 8px; text-align: left;">Parameter</th></tr><tr><td style="border: none; padding: 8px; text-align: left;"><strong>General</strong></td><td style="border: none; padding: 8px; text-align: left;"><strong>Value</strong></td></tr><tr><td style="border: none; padding: 8px; text-align: left;">SKU</td><td style="border: none; padding: 8px; text-align: left;">MXZ-5D36NL</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Model</td><td style="border: none; padding: 8px; text-align: left;">MXZ-5D36NL</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Brand</td><td style="border: none; padding: 8px; text-align: left;">Mitsubishi</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Category</td><td style="border: none; padding: 8px; text-align: left;">Heat Pumps</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Product Type</td><td style="border: none; padding: 8px; text-align: left;">Outdoor unit</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Unit Type</td><td style="border: none; padding: 8px; text-align: left;">3-Ton Inverter Condenser Heat Pump</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Product Line</td><td style="border: none; padding: 8px; text-align: left;">M-Series</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Operating Mode</td><td style="border: none; padding: 8px; text-align: left;">Cooling & Heating</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Low Ambient Heat</td><td style="border: none; padding: 8px; text-align: left;">NO</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Number of Zones</td><td style="border: none; padding: 8px; text-align: left;">5</td></tr><tr><td style="border: none; padding: 8px; text-align: left;"><strong>Performance</strong></td><td style="border: none; padding: 8px; text-align: left;"><strong>Value</strong></td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Cooling at 95F</td><td style="border: none; padding: 8px; text-align: left;">Maximum Capacity Btu/h 36,400 // 34,900 // 33,400</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Heating at 47F Maximum Capacity Btu/h</td><td style="border: none; padding: 8px; text-align: left;">43,000 // 39,000 // 35,000</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Heating at 47F Rated Capacity Btu/h</td><td style="border: none; padding: 8px; text-align: left;">36,000 // 35,200 // 34,400</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Heating at 47F Minimum Capacity Btu/h</td><td style="border: none; padding: 8px; text-align: left;">12,800 // 12,800 // 12,800</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Heating at 17F</td><td style="border: none; padding: 8px; text-align: left;">Maximum Capacity Btu/h: 26,600 // 26,600 // 26,600</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Heating at 5F</td><td style="border: none; padding: 8px; text-align: left;">Maximum Capacity Btu/h: 24,000 // 21,200 // 18,400</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Heating Minimum Temp</td><td style="border: none; padding: 8px; text-align: left;">-4 F</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Capacity</td><td style="border: none; padding: 8px; text-align: left;">36,000 BTU</td></tr><tr><td style="border: none; padding: 8px; text-align: left;"><strong>Energy Efficiency</strong></td><td style="border: none; padding: 8px; text-align: left;"><strong>Value</strong></td></tr><tr><td style="border: none; padding: 8px; text-align: left;">EER2</td><td style="border: none; padding: 8px; text-align: left;">12 //</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">SEER2</td><td style="border: none; padding: 8px; text-align: left;">19.20</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">HSPF2</td><td style="border: none; padding: 8px; text-align: left;">9.30</td></tr><tr><td style="border: none; padding: 8px; text-align: left;"><strong>Refrigerant / Piping</strong></td><td style="border: none; padding: 8px; text-align: left;"><strong>Value</strong></td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Refrigerant Type</td><td style="border: none; padding: 8px; text-align: left;">454B</td></tr><tr><td style="border: none; padding: 8px; text-align: left;">Refrigerant</td><td style="border: none; padding: 8px; text-align: left;">R454B</td></tr></tbody></table> |